descaler

Electronic Scale Preventer

€655.00 Incl. Vat

Product Description

The COMAP 5106 electronic scaling inhibitor emits an induced pulsed electrical signal that precipitates out the Ca2+ and CO32- ions present in the water, in the form of calcium carbonate crystals CaCO3. The precipitated crystals grow from a few nm to a few μm and the COMAP 5106 thus neutralises the calcium by destroying its depositing capability.

  • Removes existing scaling by gradually decomposing it
  • Prevents further scaling deposits, thus protecting the enire system, including pipes
  • Helps remove deposits due to water evaporation (by wipping off, not by abrasion) on sinks, washbasins and taps, etc.
  • Allows water heaters to remain efficient and maintain output performance
  • Operation does not involve any increase in water consumption
  • Low electricity consumption: 4.5 kW per month, i.e. less than one euro per month
  • Easy to install on new or existing pipe systems
  • Compact
  • Soft Treatment, No Servicing
  • GREEN TECHNOLOGY – No Chemical Substances

Applications
Household Cold Water Systems
Household Hot Water Systems
Operating Principle:

The COMAP 5106 electronic scaling inhibitor emits an induced pulsed electrical signal that precipitates out the Ca2+ and CO32- ions present in the water, in the form of calcium carbonate crystals CaCO3. The precipitated crystals grow from a few nm to a few μm and the COMAP 5106 thus neutralises the calcium by destroying its depositing capability. The electronic scaling inhibitor isn’t a water softener. It doesn’t change the balanced composition of the water, doesn’t remove any mineral salts and therefore doesn’t change its drinking qualities. The water is neither softened (no excess sodium or insufficient calcium) nor made aggressive.
Technical Characteristics:

  • Service pressure: from 0 to 4 bars (relative)
  • Max flow: 3000 l/h
  • Fuse: 63 mA timed
  • Electrical rating: max 10 VA
  • Waterproofing: IP 31
  • Water temperature range: +5 to +70 °C
  • Connection to single phase mains supply 230 V AC 50/60 Hz + earth
  • Protected against mains overvoltages
  • Descaling treatment power selector:
  • position 1 for water with TH < 25 °F (French Degree)
  • position 2 for water with TH ≥ 25 °F (French Degree)
  • Water hardness accepted up to 60 °F (French Degree)
  • Connections: 3/4 Inch or 1 Inch depending on model
  • No pressure drop
  • Elements in contact with water in special grade steel

 

Installation & Maintenence:

  • Easy installation. The unit is connected on the incoming water supply or on the return from the water heater loop. Horizontal or vertical installation; water transit in either direction.
  • Check that the unit and pipes are properly earthed
  • PROCESS UTILISATION LIMIT PARAMETERS: iron (0.5 mg/l), chlorides (100 mg/l), phosphates (5 mg/l), nitrates (40 mg/l), sulphates (100 mg/l), total dissolved salts (4 g/l), max. total hardness (60 °F).
  • No servicing required
  • If a filter is installed upstream of the descaling unit, the cartridge should be changed at least once per year

Additional Information: